PREMIUM
ARTICLE

Microbore pipe and heat pumps – What installers need to know

8mm and 10mm bore piping is still widely used in the UK. But with heat pumps running at four times the flow rate of a gas boiler, it can pose a problem for both installers and customers who want to switch away from fossil fuels. Viessmann partner Liam Barry, Projects Director at Custom Renewables, considers how to make it work and when to replace it. 

Can microbore work with heat pumps? The simple answer is yes, but it depends on lots of different factors. It’s a complex topic with a great many variables at play.  

Currently I come across around one heat pump installation every week that needs refitting because the installer relied on generic manufacturer schematics or kit instead of working out the system’s heat loss, radiator outputs, separation (buffers or low loss headers), flow rates, pressure losses, water volume and velocities. Without this information, you can’t answer the microbore question or specify the right set up. 

It’s often assumed that heat pumps are only suited to modern, well insulated buildings. In fact, they can and do work well in properties of all types and ages, as long as the system is well designed for the environment it’s in. That includes the pipes.  

While it’s true that some new build properties may have the high-spec insulation needed to counterbalance the constricted flow rate of microbore, older (pre-1980s) homes are more likely to have copper pipes. This is often an advantage when switching from a gas boiler to a heat pump because 10mm copper pipe has a bigger bore than 10mm plastic. In a well-insulated home with radiator outputs of around 700 Watts, you might well be able to get away with 10mm copper because the pressure loss will only be around 45mm per metre (300 kPa). But plastic would likely be a no-go as the smaller internal diameter will increase pressure loss and velocity (noise). 

Do the maths  

However, there’s much more to it. For one thing, many heat pumps use glycol which means the pump has to work harder to maintain a higher flow rate, reducing efficiency and increasing pressure loss. This makes it harder to operate with microbore.  

While microbore pipes increase velocity, they also increase pressure loss due to friction. Calculating pressure loss is key because if it’s too high, the pump won’t be able to overcome the index circuit (the part of the pipe network that experiences the highest pressure loss). If that’s the case, then you may need to split the system, if space allows, by adding separation via a buffer tank or low loss header so you can incorporate an extra pump.  

However, this will increase the overall installation and running costs, due to distortion and mixing. For optimum efficiency and lower running costs, at a Delta temperature (DT) of 5 degrees Celsius, a 5 kW unit needs around 14 l/min, a 7 kW needs 19 l/min, a 10 kW needs around 29 l/min and a 12 kW around 35 l/min.  

Length  

In general, the larger the bore and the shorter the run, the lower the pressure loss. Ideally, you want any microbore runs to be as short as possible before they join a wider branch. Older properties tend to have longer pipe runs. In the case of underfloor heating, where the run may be 80-100m, if using 10-12mm pipe, a system with separation and additional pumps is more likely to be necessary. 

Another consideration is that microbore pipes reduce the overall volume of liquid in the network, which in turn increases the number of system cycles per hour, pushing up running costs. This is particularly true during defrost cycles when heat is extracted from the living space to thaw the unit, putting a cold slug of water back into the network each time. Bigger radiators, a volumiser and/or buffer tank can help to increase volume.  

Control and engineering 

Because there are so many variables to get right when it comes to heat pump installation, it’s best to avoid pre-plumbed units that are quicker to install. Designed to be one-size-fits-all, they often include potentially unnecessary components which prevent the heat pump providing heat directly to the network, increasing distortion and reducing efficiency. 

Great weather compensation and really good in-built system controls, on the other hand, are important components of an efficient system. This is where the Viessmann Vitocal heat pumps with their user-friendly control app really come into their own.  

If you think of the heat energy in a home like a bucket of sand, heat loss is like a hole in the bottom. The only variable is external temperature; when that drops, the hole gets larger, and when it’s warmer, it shrinks. The heat pump’s job is to put the same amount of sand (energy) in the top as is lost out the bottom. Third party controls change how that happens, allowing the bucket to empty more than it’s filled so that far more energy is then needed to refill it.  

Training and support 

Getting the right low-temperature system-design training is crucial for anyone fitting heat pumps. Northampton Heating Academy and Heat Geek offer excellent courses. You can also get system-design support from Viessmann via its MCS umbrella scheme Viessmann Access.  

When it comes to heat pump installation, almost every problem can be overcome through the right set up – but there’s often a cost. Deciding whether to replace microbore comes down to a balancing act between losing efficiency and/or implementing potentially costly mitigation and improvement measures on the one hand, versus not having to undergo the expense and disruption of replacing pipes on the other. The right answer will be different for every customer, and it takes a professional with a really sound understanding of how heat pumps work to guide them through the options.  

Special offer
Get 100 points for signing up and rewards for registering your installations on VPlus. Use this link to get involved: Viessmann Portal

Viessmann is exhibiting at InstallerSHOW 2025 on 24-26 June at the NEC. Register for your FREE ticket here – parking is free too.

Don’t miss elementalLONDON 2026!

Join thousands of built environment professionals at Excel London, 25–26 November, for two days of innovation, expert insights and networking.

Discover the latest solutions in building efficiency, sustainability and decarbonisation, alongside London Build and CIBSE Build2Perform.

Find out more and secure your free ticket