IGEM/UP/1B Edition 4: what installers need to know about the updated tightness test 

Steve Sutton

From 1 October 2026, gas operatives must use IGEM/UP/1B Edition 4 when carrying out tightness testing and direct purging of small LPG/Air, natural gas and LPG installations. Steve Sutton, Technical Manager, Heating and Hotwater Industry Council (HHIC) explains:

Published in March 2026, Edition 4 replaces Edition 3, which was withdrawn on 30 September 2026.  A six-month transition period has allowed installers time to familiarise themselves with the changes and adopt the new procedures. 

While the fundamental approach to carrying out a tightness test remains the same, there are some important changes that installers need to understand.  The most significant is the move away from using meter size as the basis for determining permissible pressure drops.  Under IGEM/UP/1B Edition 4, Installation Volume (IV) is now the key factor. 

Installation Volume becomes central to the test 

IGEM/UP/1B Edition 4 applies to gas installations, including meters, where the maximum operating pressure at the outlet of the emergency control valve does not exceed 2 bar for NG and LPG/Air; the nominal bore is no greater than 35 mm (DN32, R1¼); the primary meter has a maximum badged capacity of 16 m³/h; and the installation volume supplying an individual dwelling or non-domestic premises does not exceed 0.035 m³.  The operating pressure at the outlet of the primary meter and throughout the test section must not exceed 21 mbar for NG or LPG/Air, or 37 mbar at the outlet of the final-stage regulator and throughout the test section for LPG.  IGEM/UP/1B Edition 4 can also be used for small sections of a larger installation as long as they meet the above requirements  

The standard also specifies the applicable operating pressures for NG, LPG/Air and LPG installations. 

Under the previous edition, permissible pressure drops were linked to meter size.  IGEM/UP/1B Edition 4 recognises that the actual volume of the installation being tested is a more appropriate factor. 

IV comprises the volume of the pipework, the meter where it forms part of the test section and the volume associated with fittings.  Heating engineers therefore need to calculate the IV of the section being tested and use the relevant table in the standard to establish the permissible pressure drop for the fuel gas. 

For example, pipework volume can be calculated from the length and internal volume per metre, while fittings volume is typically accounted for as 10% of the pipework volume.  Where pipework is concealed, engineering judgement should be used to estimate its length and, where the size cannot be established, the largest known pipe size should be assumed.  This provides a conservative IV calculation. 

IGEM/UP/1B Edition 4 also provides clarity around what constitutes ‘perceptible movement’.  For a fluid, water-filled gauge, movement of up to 0.25mbar is considered to be no perceptible movement.  For an electronic gauge reading to 1 decimal place, a reading of up to 0.2mbar is considered to be no perceptible movement. 

Following the let-by test and establishment of the correct tightness test pressure, the installation is allowed to stabilise for one minute before the two-minute tightness test is carried out.  If there is no perceptible movement, the test passes, provided there has been no reported smell of gas. 

The pipework-only retest is a key change 

One of the most important practical changes in IGEM/UP/1B Edition 4 is what happens when perceptible movement is identified. 

Where perceptible movement is observed during the initial test, the appliances must be isolated and the tightness test repeated on the installation pipework alone.  There must be no perceptible movement during this pipework-only test. If the pipework passes, the pressure drop previously observed with the appliances connected must then be assessed against the permissible limit for the fuel gas and the calculated Installation Volume. 

If movement is detected during the retest, the installation pipework has failed the test and the escape must be traced and repaired, or the installation made safe in accordance with the relevant industry procedures. 

Where it is not practicable or possible to isolate an appliance, the test must be carried out with that appliance connected and the no-perceptible-movement criterion applied. 

This additional check is an important part of IGEM/UP/1B Edition 4.  It provides greater certainty that any pressure drop identified during the initial test is not coming from the installation pipework itself. 

It is important to understand that these permissible pressure-drop limits are intended to account for the possibility of small amounts of gas passing through connected existing appliances.  They do not mean that a pressure drop attributable to installation pipework is acceptable. 

Tightness test pressure  

IGEM/UP/1B Edition 4 introduces a new note covering situations where the minimum tightness test pressure cannot be achieved.  Where the required minimum pressure for the fuel gas cannot be reached, the installation must be isolated and the cause of the low pressure investigated before proceeding. 

For natural gas, where 20mbar cannot be achieved, the tightness test may be carried out at a minimum of 18mbar.  If the test is successful at this lower pressure, operating pressure checks must then be carried out in accordance with IGEM/G/13. 

Installers should therefore not simply proceed with a tightness test at an insufficient pressure without first establishing why the required pressure cannot be achieved. 

Purging: calculate the volume rather than rely on assumptions 

IGEM/UP/1B Edition 4 also changes the way purge volume is determined.  Previously, certain small installations could use an assumed purge volume.  Under the new procedure, installers must calculate the Installation Volume and then determine the purge volume using PV = 1.5 × IV. 

The purge procedures themselves remain the same.  For natural gas, installations are purged to air for purge volumes up to 0.02m³ and purged to ignition where the purge volume exceeds 0.02m³. LPG and LPG/Air installations are purged to ignition. 

This means that calculating IV is now an important part of both the tightness testing and purging processes. 

What installations are covered? 

The standard applies to tightness testing in a range of circumstances, including new installations, alterations, replacements, reuse or upgrading of existing installations, new extensions and work that may affect gas tightness. 

It also applies where there is a known or suspected gas escape, following complete loss of supply or installation pressure, during routine testing of existing installations, and immediately before purging. 

For direct purging, the standard covers new installations, alterations, replacements, reuse and extensions to existing installations, as well as situations where installation pressure has been completely lost or where there is a possibility of extraneous air being present. 

IGEM/UP/1B Edition 4 also expands the scope to include caravans and leisure accommodation vehicles within the relevant criteria. 

Don’t switch between editions 

The six-month transition period has now ended.  From 1 October 2026, IGEM/UP/1B Edition 4 is the applicable standard. 

Where an installer has adopted IGEM/UP/1B Edition 4 and a tightness test fails, it is not acceptable to retrospectively apply IGEM/UP/1B Edition 3 in an attempt to obtain a pass. 

The appropriate action is to trace and repair the escape or make the installation safe in accordance with the relevant procedures.  The Gas Safe Register also recommends recording which edition of the tightness testing procedure has been applied on work records. 

Getting to grips with IGEM/UP/1B Edition 4 

For installers, the main message is that the practical principles of tightness testing have not been fundamentally changed.  However, the new standard introduces a more clearly defined and volume-based approach to assessing pressure drops. 

The key points to remember are: 

  • Installation Volume is now central to determining permissible pressure drops. 
  • Perceptible movement is defined numerically for both fluid and electronic gauges. 
  • A pipework-only retest is required where movement is detected during the initial test. 
  • There can be no perceptible movement during the pipework-only test. 
  • Purge volume is calculated from Installation Volume using PV = 1.5 × IV. 
  • IGEM/UP/1B Edition 4 is now the applicable procedure, following the withdrawal of IGEM/UP/1B Edition 3 on 30 September 2026. 

The changes are intended to provide a more consistent and robust approach to tightness testing and direct purging, while giving gas operatives clearer criteria against which to assess installations. 

For heating engineers who have not yet incorporated IGEM/UP/1B Edition 4 into their working practices, now is the time to make sure procedures, equipment, calculations and work records reflect the new requirements.  It is recommended that engineers have access to a copy of the standard to ensure they can demonstrate compliance. 

Don’t miss elementalLONDON 2026!

Join thousands of built environment professionals at Excel London, 25–26 November, for two days of innovation, expert insights and networking.

Discover the latest solutions in building efficiency, sustainability and decarbonisation, alongside London Build and CIBSE Build2Perform.

Find out more and secure your free ticket